5 Data Center Cooling Mistakes You Should Avoid

avatar
Hunter Hex
5 Data Center Cooling Mistakes You Should Avoid

Summary: Looking for the best dc air condition will not suffice your data center cooling requirements if you commit these 6 data center cooling mistakes.

While there is a drastic improvement in the cooling management awareness, there are still some lingering issues that need to be addressed (including capacity and efficiency gains of cooling management improvements. Only using a 48vdc air conditioner should not be the goal, but make sure to improve IT equipment intake air temperatures in a way that allows for increasing cooling control temperature set point. 

Since efficiency is vital to controlling data center cooling costs and delivering consistent uptime service, here are six mistakes data center managers need to avert.

  1. Bad Cabinet Layout

The perfect cabinet layout should comprise of hot-aisle and cold-aisle data center cooling design with your computer room air handlers at the end of each row. Make sure not to an island configuration without a well-designed orientation as the use of it would be futile.

  1. Empty Cabinets

Do you want that hot exhaust air to leak back into your cold aisle? Obviously no, right? You should be aware of the fact that empty cabinets can skew airflow. So, if you have cabinets, make sure your cold air is contained.

  1. Enough Spaces Between Equipment

Is your data center have cabinets with empty, uncovered spaces between the hardware? These spaces can damage your airflow management. If this is not acknowledged then, spaces between the cabinet can be the underlying reason for hot air leaking back into your cold aisle. So, make sure that you seal these spaces. 

  1. Leaks Around Cable Openings

There are a plethora of openings in floors and cabinets for cable management. While experts are under the raised floor scrutinizing the leaks, they should also find unsealed cable openings, holes under remote power panels, and power distribution units. Seal these holes as it will let cold air escape. It could also be a significant reason for increasing your ac requirement and expenditure.

  1. Raised Floor Leaks

Such leaks occur when cold air leaks under your raised floor and into support columns or other spaces. It leads to loss of pressure, which allows dust, humidity, and warm air to enter your cold aisle environment. To resolve such leaks, someone will need to do a full inspection of the support columns and perimeter and seal any leaks they find.

So, make sure to look into these issues and invest in the best 48v lithium battery to get the desired cooling. 